AXIOM PHYSICS Class 12 • Module 7.3

Unit 04: Alternating Current • Chapter 07

Power Factor, Wattless Current & The Transformer

Real vs apparent power, power factor correction, quadrature wattless current, mutual flux induction, and laminated core losses.

⚡ 01. The Spark (Analogy)

Socho ek fizzy cold drink ke glass ko: glass mein jo liquid hai woh asal drink hai jise aap peete hain (Active / Real Power: $P = V_{\text{rms}}I_{\text{rms}}\cos\phi$), lekin upar jo jhaag (foam) banta hai woh glass ki jagah toh gher leta hai par pyaas nahi bujhata (Wattless / Reactive Current: $I_{\text{rms}}\sin\phi$). Poora glass foam samet Apparent Power ($V_{\text{rms}}I_{\text{rms}}$) hai. Agar jhaag zyada ho, toh electricity company ke motey taar bekar mein current carry karte hain bina koi useful work kiye! Aur jab is power ko hazaron kilometer door bhejna hota hai, toh raste mein taaron ki garmi ($I^2R$) se bachne ke liye hum Transformer use karte hain: voltage ko hazaron guna badha kar current ko lagbhag zero kar diya jaata hai, taaki energy bina loss ke safely transport ho sake!

📐 02. The Core Law & Formulae

1. AC Power & Wattless Current

Average power dissipated over a complete cycle:

$$P_{\text{avg}} = V_{\text{rms}} I_{\text{rms}} \cos\phi = \text{Apparent Power} \times \text{Power Factor}$$ $$\text{Power Factor } \cos\phi = \frac{R}{Z} = \frac{\text{True Power}}{\text{Apparent Power}}$$ $$I_{\text{wattless}} = I_{\text{rms}} \sin\phi \quad (\text{Consumes zero average power})$$

Pure $L$ or $C$: $\phi = 90^\circ \implies \cos 90^\circ = 0 \implies P_{\text{avg}} = 0$. Resonance / Pure $R$: $\phi = 0^\circ \implies \cos 0^\circ = 1$ (Maximum power).

2. Ideal Transformer Equations

Mutual flux linkage ratio with 100% efficiency:

$$\frac{V_s}{V_p} = \frac{N_s}{N_p} = \frac{I_p}{I_s} = k \quad (\text{Transformation Ratio})$$ $$\eta = \frac{P_{\text{output}}}{P_{\text{input}}} \times 100\% = \frac{V_s I_s}{V_p I_p} \times 100\%$$

Step-up Transformer: $k > 1$ ($N_s > N_p, V_s > V_p, I_s < I_p$). Step-down Transformer: $k < 1$ ($N_s < N_p, V_s < V_p, I_s > I_p$).

03. Interactive Visualizer: Mutual Induction Transformer Engine
Primary Voltage ($V_p$) 120 V
Turns Ratio ($N_s / N_p$) 2.50 (Step-Up)
Secondary Load ($R_L$) 50.0 Ω
Secondary Output ($V_s$):
300.0 V
Secondary Current ($I_s$):
6.00 A
Primary Current ($I_p$):
15.00 A
Transfer Power ($P_{\text{in}} \approx P_{\text{out}}$):
1800 W (Ideal)
📝 04. Comprehensive Stepwise Derivations Blueprint
Derivation A

Average Power in AC Circuit & The Power Factor

1. Let applied instantaneous alternating voltage and resulting current with phase difference $\phi$ be:

$$v = V_0 \sin\omega t, \quad i = I_0 \sin(\omega t - \phi)$$

2. Instantaneous power delivered to the circuit: $p = v \times i$:

$$p = (V_0\sin\omega t) \times [I_0\sin(\omega t - \phi)] = V_0 I_0 \sin\omega t [\sin\omega t\cos\phi - \cos\omega t\sin\phi]$$ $$p = V_0 I_0 \sin^2\omega t\cos\phi - V_0 I_0 \sin\omega t\cos\omega t\sin\phi$$

3. Using trigonometric identities $\sin^2\omega t = \frac{1 - \cos 2\omega t}{2}$ and $\sin\omega t\cos\omega t = \frac{\sin 2\omega t}{2}$:

$$p = \frac{V_0 I_0}{2} (1 - \cos 2\omega t)\cos\phi - \frac{V_0 I_0}{2} \sin 2\omega t\sin\phi$$

4. Average power over a complete cycle of time period $T$ ($P_{\text{avg}} = \frac{1}{T}\int_0^T p \, dt$):

• The time averages over a full cycle are: $\langle 1 \rangle = 1$, $\langle \cos 2\omega t \rangle = 0$, and $\langle \sin 2\omega t \rangle = 0$.

$$P_{\text{avg}} = \frac{V_0 I_0}{2}\cos\phi - 0 = \left(\frac{V_0}{\sqrt{2}}\right)\left(\frac{I_0}{\sqrt{2}}\right)\cos\phi$$
$$P_{\text{avg}} = V_{\text{rms}} I_{\text{rms}} \cos\phi \quad \text{where } \cos\phi = \frac{R}{Z}$$
Derivation B

Resolution of Current: Active Component vs Wattless Component

O V_rms (Voltage Reference) I_rms φ I_rms cosφ (Active / In-Phase) I_rms sinφ (Wattless) Angle with V_rms = 90°

Fig 7.3A: Resolution of current phasor $\vec{I}_{\text{rms}}$ into active power component ($I_{\text{rms}}\cos\phi$) and wattless component ($I_{\text{rms}}\sin\phi$).

1. In an AC circuit where current lags voltage by phase angle $\phi$, resolve $\vec{I}_{\text{rms}}$ into two orthogonal components:

• Active Component: $I_{\text{active}} = I_{\text{rms}}\cos\phi$ along $\vec{V}_{\text{rms}}$ (in-phase, phase difference $= 0$).

$$P_1 = V_{\text{rms}} (I_{\text{rms}}\cos\phi) \cos 0^\circ = V_{\text{rms}} I_{\text{rms}}\cos\phi \quad (\text{Real Consumed Power})$$

• Wattless Component: $I_{\text{wattless}} = I_{\text{rms}}\sin\phi$ perpendicular to $\vec{V}_{\text{rms}}$ (in quadrature, phase difference $= 90^\circ$).

$$P_2 = V_{\text{rms}} (I_{\text{rms}}\sin\phi) \cos 90^\circ = 0 \quad (\text{Wattless Power})$$

2. Definition: The component of AC current which consumes zero average power over a complete cycle ($P_2 = 0$) is known as the Wattless Current ($I_{\text{rms}}\sin\phi$).

Derivation C

Transformer Principle, Formulation of Turns Ratio & Energy Losses

1. Principle: Works on the principle of Mutual Induction—whenever current in the primary coil changes, magnetic flux linked with the secondary coil changes, inducing an alternating EMF across it.

2. Let an alternating voltage $V_p$ be applied across the primary coil of $N_p$ turns. Let the common magnetic flux linked per turn of the soft iron core be $\Phi$.

3. Induced EMF in the primary coil (by Faraday-Lenz law):

$$\mathcal{E}_p = -N_p \frac{d\Phi}{dt}$$

4. The same mutual flux $\Phi$ threads each of the $N_s$ turns of the secondary coil. Induced EMF in the secondary coil:

$$\mathcal{E}_s = -N_s \frac{d\Phi}{dt}$$

5. Assuming ideal conditions (negligible winding resistance and zero flux leakage, so $\mathcal{E}_p = V_p$ and $\mathcal{E}_s = V_s$):

$$\frac{V_s}{V_p} = \frac{N_s}{N_p} = k \quad (\text{Transformation Ratio})$$

6. For an ideal transformer with zero power loss ($P_{\text{input}} = P_{\text{output}} \implies V_p I_p = V_s I_s$):

$$\frac{V_s}{V_p} = \frac{N_s}{N_p} = \frac{I_p}{I_s} = k$$

Four Major Energy Losses in Practical Transformers & Their Minimization:

• 1. Copper Loss ($I^2R$): Joule heat in copper windings. Remedy: Use thick copper wire with low resistance for high-current coils.

• 2. Eddy Current Loss: Circulating induced currents in the solid iron core. Remedy: Use a laminated core composed of thin sheets insulated by varnish.

• 3. Hysteresis Loss: Energy wasted in repeated cyclic magnetization and demagnetization of the core. Remedy: Use soft iron which has a very narrow hysteresis loop.

• 4. Flux Leakage: All flux produced by primary does not thread secondary. Remedy: Wind secondary directly over primary in a coaxial arrangement.

⚠️ 05. Red Alert Exam Trap Zone

Trap 1: Connecting a Transformer to a DC Battery Source

*Board Question:* What happens if a $12\text{ V}$ DC battery is connected across the primary of a step-up transformer?
• DC produces a constant, steady magnetic flux ($d\Phi/dt = 0$).
• Secondary voltage is strictly ZERO ($V_s = 0$) because induction requires changing flux!
• In primary, back-EMF is zero ($X_L = 0$); only tiny ohmic resistance $R_p$ opposes current. A massive direct current flows, and the primary coil burns out immediately!

Trap 2: High Voltage Long-Distance Transmission Logic

*Why transmit power at $400{,}000\text{ V}$ instead of $220\text{ V}$?*
Power to be transmitted is constant: $P = V I \implies I = P/V$.
Heat loss in transmission cables of resistance $R_c$: $$P_{\text{loss}} = I^2 R_c = \left(\frac{P}{V}\right)^2 R_c = \frac{P^2 R_c}{\mathbf{V^2}} \propto \frac{1}{V^2}$$ Stepping up voltage by a factor of $100$ reduces line power losses by a factor of $10{,}000$ ($100^2$)!

Trap 3: Conservation of Energy in Step-Up Transformers

Does a step-up transformer violate Conservation of Energy because $V_s > V_p$?
NO! When voltage increases ($V_s > V_p$), the current decreases in the exact same proportion ($I_s < I_p$). Power output can never exceed power input: $P_s \le P_p$. Voltage is stepped up at the expense of current!

Trap 4: Frequency Invariance through a Transformer

A transformer changes voltage and current, but the frequency of the AC supply remains strictly UNCHANGED ($f_s = f_p$). If input is $50\text{ Hz}$, output is always $50\text{ Hz}$.

💡 06. Handcrafted Exemplars
Board Classic Level

Problem: A transformer has 200 turns in the primary coil and 800 turns in the secondary coil. The primary is connected to an AC mains supply of $220\text{ V}, 50\text{ Hz}$. If a load of resistance $440\text{ }\Omega$ is connected across the secondary, find (i) secondary voltage, (ii) secondary current, (iii) primary current, and (iv) input power, assuming an ideal transformer.

Solution:

1. Given: $N_p = 200$, $N_s = 800$, $V_p = 220\text{ V}$, $R_L = 440\text{ }\Omega$.

Transformation ratio $k = \frac{N_s}{N_p} = \frac{800}{200} = 4$ (Step-Up).

$$V_s = k \times V_p = 4 \times 220\text{ V} = 880\text{ Volts}$$

2. Secondary current ($I_s$):

$$I_s = \frac{V_s}{R_L} = \frac{880\text{ V}}{440\text{ }\Omega} = 2.0\text{ Amperes}$$

3. Primary current ($I_p$):

$$\frac{I_p}{I_s} = \frac{N_s}{N_p} = 4 \implies I_p = 4 \times I_s = 4 \times 2.0 = 8.0\text{ Amperes}$$

4. Input power:

$$P_{\text{in}} = V_p I_p = 220 \times 8.0 = 1760\text{ Watts} \quad (P_{\text{out}} = V_s I_s = 880 \times 2.0 = 1760\text{ W})$$
JEE/NEET Competitive Trap

Problem: In a series circuit, an alternating voltage $v = 200\sqrt{2}\sin(100t)\text{ V}$ produces a current $i = 5\sqrt{2}\sin(100t - \frac{\pi}{3})\text{ A}$. Calculate (i) peak and RMS voltage and current, (ii) power factor of the circuit, (iii) average active power consumed, and (iv) magnitude of the wattless current.

Solution:

1. From given equations: $V_0 = 200\sqrt{2}\text{ V} \implies V_{\text{rms}} = 200\text{ V}$.

$I_0 = 5\sqrt{2}\text{ A} \implies I_{\text{rms}} = 5\text{ A}$. Phase angle $\phi = \frac{\pi}{3} = 60^\circ$.

2. Power factor:

$$\cos\phi = \cos 60^\circ = 0.50 \quad (\text{Lagging})$$

3. Average real power consumed:

$$P_{\text{avg}} = V_{\text{rms}} I_{\text{rms}} \cos\phi = 200 \times 5 \times 0.50 = 500\text{ Watts}$$

4. Wattless current component:

$$I_{\text{wattless}} = I_{\text{rms}} \sin\phi = 5 \times \sin 60^\circ = 5 \times \frac{\sqrt{3}}{2} \approx 4.33\text{ Amperes}$$
🗂️ 07. Quick Revision Flashcard Core Formulae

Power Factor

$\cos\phi = \frac{R}{Z}$

Wattless Current

$I_w = I_{\text{rms}}\sin\phi$ ($P=0$)

Turns Ratio

$k = \frac{V_s}{V_p} = \frac{N_s}{N_p} = \frac{I_p}{I_s}$

Laminated Core

Cuts Eddy Current Loss